Vertical & Horizontal Check Valves
Resistoflex Horizontal and Vertical Poppet-Type Check Valves are
plastic-lined for handling corrosives and high-purity fluids. They are
extremely effective in preventing back-pressure or backflow, feature a
low 0.5 psi (0.03 bar) cracking pressure differential, and are capable
of handling pressures to 275 psi (19 bar). Liner materials of
polypropylene resin, PVDF resin, or PFA resin are available, depending
on the valve size and type.
Full size ports for maximum capacity
Resistoflex Check Valves, available in 1” through 8” sizes, have full
pipe diameter ports and provide minimal obstruction in the flow path.
The poppet-type design of the vertical check valves eliminates problems
that occur in some check valves with pockets that can trap fluid.
Practically maintenance-free
Since Resistoflex Check Valves have only one moving part, they are less
likely to need maintenance. Because every surface in contact with the
fluid is made of or covered with a thick layer of plastic, corrosion
and contamination are vitually eliminated.
Available models and sizes
| Size, inches |
1 |
1 1/2 |
2 |
3 |
4 |
6 |
8 |
| Body Material |
DI |
CS |
DI |
CS |
DI |
CS |
DI |
CS |
DI |
CS |
DI |
CS |
DI |
CS |
| PP |
X |
X |
X |
X |
X |
X |
X |
X |
X |
X |
X |
X |
X |
X |
| PVDF |
|
X |
|
X |
|
X |
|
X |
|
X |
|
X |
|
X |
| PFA |
|
X |
|
X |
|
X |
|
X |
|
X |
|
|
|
|
DI = Ductile Iron CS = Cast Steel |
Pressure/temperature ratings for Resistoflex check valves
 |
|
1. Class 150 Cast Steel 1" - 4" valves
2. Class 150 Cast Steel 6" - 8" valves
3. Class 150 Ductile Iron
†Maximum liner/diaphragm capabilities may be lower depending on the
agressiveness of the fluid being handled. Refer to the
Chemical Resistance Guide. |
Calculating pressure drop
The Cv values given in the table below can be used to approximate pressure drop
(ΔP), in psig, across the valve when the required flow (Q) in gallons per minute
is know by using the following formula: G = specific gravity
ΔP = G(Q/Cv)2
Positioning hint for check valves
To prevent excessive poppet wear, it is recommended that the piping from the pump
discharge to the valve be at least 10 feet in length and include a change in
direction.
Valve Cross Reference
Horizontal Check Valve Dimensions
Vertical Check Valve Dimensions
Valve Specifications
Storage, Installation, Testing,
Operation and Maintenance Guidelines for Vertical Check Valves |
"This page is a machine translation of the source page, which is written in
English. This translation is intended to provide a general idea of the
page's content, and is not guaranteed for accuracy."
|