Pressure Ratings of PTFE Expansion Joints


Non-Shocking Working Pressure vs. Temperature R6904 2-Convolution PTFE Expansion Joints


Non-Shocking Working Pressure vs. Temperature R6905 3-Convolution PTFE Expansion Joints


Non-Shocking Working Pressure vs. Temperature R6906 5-Convolution PTFE Expansion Joints

Vacuum Data
Maximum Temperature for Full Vacuum
(29.9" Hg)
Size (in.) R6904 R6905
1-3 425°F 400°F
4 400°F 400°F
5-6 400°F 300°F
8 250°F 125°F
10 250°F ---
12 75°F ---
Note: These ratings are for flexible couplings or expansion joints in the fully extended condition. When they are the neutral lengths or compressed, it is sometimes possible to exceed the listed temperature at full vacuum. Consult factory.

5-Convolute Expansion Joint (R6906) is not recommended for vacuum service.